Improve X-ray images using quality assurance tests

Author:

Alhamd M. W.,Jary Aqeel Maryoosh,Atiyah Sadeq Naeem,Abbood Nazar Ali

Abstract

Abstract In this research, entrance surface doses of patients which are resulted from a classical radiograph in most widespread tests (Chest, skull, abdomen, limbs, …) have been measured with selected instruments in (Specialized surgeries hospital) and one of the private clinic in Baghdad, the instruments are of various origins and different make date. A group of patients (10 patients) for each test and according the average of the resulted doses. Comparison of the patient’s doses, in this research, has been close with the reliable International standards and it has been found that radiological doses are bigger than reference doses ranging (132–1.79) in most of the appliance and the range doses to one whenever the instrument is new and the radiographer has good experience, this increase relates to several functions discussed in the research in detail For the importance of the quality assurance of x-ray instruments, three tests have been performed by three of the instruments only, and these tests are : Beam Alignment test : The Beam Alignment was measured and the x-ray radiograph was found symmetrical round the two axes of the instruments (A, B) but it is about 3 ° away from the vertical axis of the instrument (C). Optical and Radiation Field Congruence Test: The light field coincides with the radiative field in a and b and their mismatch in c. Focal Spot Size Test: The radiation focus area was measured by the star tool and what appeared is that the focus of the x-ray instrument (C) is smaller than the international standards on the contrary of the focus area of the x-ray instrument (E) which is identical with the international standards. From these results reached is that the instruments (A, B) have passed quality assurance tests and they are suitable for work in the present, but the instrument (C) has not passed most of the quality assurance tests, so this instrument should not be used for medical tests This in research is considered the first one for these instruments to evaluate their doses or measure a quality assurance.

Publisher

IOP Publishing

Subject

General Physics and Astronomy

Reference12 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3