Author:
Lu Jiamin,Liu Li,Chen Guoyu,Li Jinjin,Li Cheng,Liu Yajun
Abstract
Measuring with Coriolis flowmeter under the condition of gas-liquid two-phase flow, the vibration signal frequency, phase and amplitude of the measuring pipe fluctuate randomly. The traditional phase difference extraction algorithm is difficult to ensure the measurement accuracy of mass flow. In order to improve the extraction accuracy of mass flow, this paper presents a dynamic error correction method of mass flow based on LSTM (Long Short-Term Memory). The water flow test platform and data acquisition system are built, and the mass flow corrected by this method is compared with the mass flow corrected by ARMA (Autoregressive moving average) model and the mass flow obtained by flow meter. The experimental results show that the mean error of mass flow corrected by this method is 0.0357, and the variance is 0.0453, which is far less than the static error correction of 0.0988 and 0.1068, and far less than the mass flow meter of 0.3816 and 0.4045.
Subject
General Physics and Astronomy
Reference17 articles.
1. Optical fibre void fraction detection for liquid metal fast neutron reactors;Corazza;Experimental Thermal and Fluid Science,2020
2. Effect of the inlet gas void fraction on the tip leakage vortex in a multiphase pump;Shi;Renewable Energy,2020
3. Numerical investigation of gas-liquid two-phase flows in a cylindrical channe;Gourari;Defect and Diffusion Forum,2021
4. Hydrodynamic forces acting on pipe bends in gas-liquid slug flow;Tay;Chemical Engineering Research & Design,2014
5. Study on measuring gas-liquid two-phase flow with micro-bend type coriolis mass flowmeter;Dong;Chinese Journal of Scientific Instrument,2015