Breakdown Characteristics of Long Air Gap at Different Frequency Based on Series Resonance

Author:

Hu Zhengyong,Xu Peng,Tan Wenlong,Gao Kai,Cui Lv

Abstract

Abstract In today’s rapid economic development, with the development of science and technology, higher requirements have been put forward in the economic operation of the system. This requires various departments to make more reasonable use of existing energy and equipment, and to ensure quality. Meet all aspects of supply with more energy-saving and more economical operation methods. Therefore, more and more attention has been paid to the research on the method of predicting the breakdown voltage of the air gap. Although domestic and foreign scholars have used power frequency test transformers to carry out a large number of long air gap experimental researches, the research on the breakdown voltage of long air gaps based on the principle of vector machines is still blank. In this paper, a vector machine test device is used to study the breakdown discharge characteristics of a long air gap at two frequencies of 229Hz and 68Hz. Comparing the test phenomena at different frequencies, it is found that the initial discharge voltage of the streamer corona is lower when the frequency is 229Hz, and the discharge phenomenon before breakdown is more intense, and the quality factor will be significantly reduced due to the violent discharge. At the same time, under the same test conditions, the breakdown voltage at 229Hz is lower than that at 68Hz, and as the air gap increases, the difference between the two is greater. The experimental results show that the breakdown voltage of the long air gap based on the vector machine is different when the frequency is different, and the safety distance of the field withstand voltage test should be evaluated according to the experimental data under the vector machine condition to ensure the safety of the test.

Publisher

IOP Publishing

Subject

General Physics and Astronomy

Reference12 articles.

1. Experimental research on vacuum breakdown characteristics in a long gap under microsecond pulses [J];Zhao;IEEE Transactions on Dielectrics and Electrical Insulation,2020

2. Breakdown characteristics of CF3I-N2 gas mixtures in a needle-plate geometry [J];Zhao;IEEE Transactions on Dielectrics and Electrical Insulation,2017

3. Resonance Characteristics Analysis of Grid-connected Inverter Systems based on Sensitivity Theory [J];Wu;Journal of Power Electronics,2018

4. Monitoring of bacterial film formation and its breakdown with an angular-based surface plasmon resonance biosensor [J];Filion-Cote;The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry,2017

5. Series and Parallel Resonance Active Damping of Three-phase Buck-type Dynamic Capacitor for Reactive Compensation and Harmonic Suppression [J];Chao;IET Power Electronics,2020

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. On-Site AC Withstand Voltage Safety Distance Evaluation of Switchgear Based on Series Resonance Principle;The proceedings of the 10th Frontier Academic Forum of Electrical Engineering (FAFEE2022);2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3