Author:
Sebelev A.A.,Tikhonov A.S.,Aleksenskiy V.A.,Shengals A.A.,Klyavin O.I.
Abstract
Abstract
This paper presents the results of an aerodynamic analysis of a small-scaled transonic centrifugal compressor for micro turbojet engine (TJE) applications. The analysis was conducted using a CFD model validated by experimental data collected for the gaged JetCat P200-RX micro-TJE. The loss coefficients of the impeller, vaned diffuser and deswirler were estimated for 4 design points corresponding to 70%, 80%, 90% and 100% rotation speeds to perform the loss balance diagram. The flow angle spanwise variation demonstrated an intensive flow separation zone at the top 25% of the vaned diffuser span due to the pressure shock appearance. It was shown that the main source of the losses in the investigated compressor is the deswirler due to non-optimal flow turning conditions. The diffuser loss coefficient was estimated as 0.18 at the compressor full load.
Subject
General Physics and Astronomy
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献