Two-stage control algorithm for magnetic fluid deformation mirror with dual-layer actuators
-
Published:2023-04-01
Issue:1
Volume:2477
Page:012092
-
ISSN:1742-6588
-
Container-title:Journal of Physics: Conference Series
-
language:
-
Short-container-title:J. Phys.: Conf. Ser.
Author:
Guo Shuo,Fu Dongjie,Ding Haichun,Liu Tianqi,Zhou Kunhua,Iqbal Azhar,Wu Zhizheng
Abstract
Abstract
To increase the correction effectiveness of full-order aberration, a control system based on a magnetic fluid flexible mirror with dual-layer actuators is presented. The combined magnetic field created by the Maxwell coil and the double-layer driving coils controls the geometry of the magnetic fluid surface. A model-based optical sensorless control approach for lower layer coils is developed and aimed to enable high magnitude restoration of lower-order aberrations. An adaptive important factor that causes on Youla parameterization, on the other hand, is developed for the upper coils to rectify higher-order residual aberrations. Matlab is used to simulate the algorithm in order to test its performance in full-order aberration correction, and the results reveal that the approach has good correction performance.
Subject
Computer Science Applications,History,Education
Reference6 articles.
1. Modeling and evaluation of magnetic fluid deformable mirror with dual-layer actuators[J];Zhang;International Journal of Optomechatronics,2019
2. Adaptive optical optimization correction algorithm based on wavefront gradient squared [J];Wen;Advances in Lasers & Optoelectronics,2019
3. Wavefront sensorless adaptive optics: a general model-based approach[J];Lin;Optics express,2011