Author:
Yamaguchi Hiroto,Suzuki Hiroki,Kouchi Toshinori
Abstract
Abstract
This study aims to experimentally examine conditions that should be satisfied by a calibration position of a constant-temperature hot-wire anemometer. Specifically, this study addresses an appropriate measurement point when this calibration is performed downstream of a turbulent field generated by a multi-scale turbulence grid. The hot-wire measurement in this study is based on an I-type probe with a standard 5 μm tungsten wire. The hot-wire anemometer in this study is small and can be attached to a probe support. In this study, uncertainty in the calibration curve of the hot-wire measurement is first checked. Here, Pitot tube velocimetry to obtain the calibration curves is carried out using two bell-type micro-differential pressure gauges. Then, the characteristics of the obtained velocity fluctuations and turbulence will be examined. Based on this relative velocity fluctuation RMS value, the effects of the obtained streamwise velocity fluctuation on output voltage are obtained by asymptotically expanding a calibration curve. Using these results, the intensity of the free-stream turbulence, which has a negligible effect on output voltage giving a calibration curve, is clarified.