Author:
Hua Chaoyue,Weng Jiahua,Yan Jia’ning,Cui Xiaoyu
Abstract
Abstract
A reasonable theoretical calculation model is established, and an appropriate correlation formula is selected to calculate the flow and heat transfer of CO2 gas flowing through micro-pin fin arrays in a micro-cooler respectively under different working conditions. The inlet pressure of CO2 gas is 1.0 MPa, 1.5 MPa, and 2.0 MPa respectively, and the inlet temperature is 12 °C and 16 °C respectively. The results show that the cold end temperature of the gas decreases with the increase of CO2 gas inlet pressure and the decrease of inlet temperature, and the lowest temperature reaches -29.93 °C. The calculated results have the same trend as the experimental data, and the calculated values are consistent with the experimentally measured values, which demonstrates the calculation model’s logic.
Subject
Computer Science Applications,History,Education
Reference16 articles.
1. Analysis on Spacecraft Development for Thermal Control Technology [J];Hanlin;Spacecraft Engineering,2010
2. Design and optimization of coil finned-tube heat exchangers for cryogenic applications [J];Gupta;Cryogenics,2007
3. Developing heat transfer in a rectangular duct with a staggered array of short pin fin [J];Metzger;Journal of Heat Transfer,1982
4. Thermodynamic Investigation and Optimization of a Joule-Thomson Cryocooler [J];Xin;Journal of Engineering thermos physics,2015
5. Experimental and numerical study on a miniature Joule-Thomson cooler for steady state characteristics [J];Ng;International Journal of Heat and Mass Transfer,2002