Mechanism of Seebeck coefficient variation at the output of NiCr/NiSi thin film thermocouple with different wires
-
Published:2024-03-01
Issue:1
Volume:2724
Page:012001
-
ISSN:1742-6588
-
Container-title:Journal of Physics: Conference Series
-
language:
-
Short-container-title:J. Phys.: Conf. Ser.
Author:
Liu Zhihui,Guo Tengda,Cheng Yongjun,Wang Bi,Shen Kai,Hu Kai,Zhou Jiankang,Zhang Chuanbing,Wang Zixi,Ding Wanyu
Abstract
Abstract
In this paper, by using magnetron sputtering to prepare NiCr/NiSi thin film thermocouples, the static calibration method is used for NiCr/NiSi thermocouples with rapid temperature calibration experiments. Different temperature calibration curves are obtained. The Seebeck coefficient of NiCr/NiSi thin film thermocouples connected to NiCr/NiSi wires is significantly higher (41.39 μV/°C) than that of NiCr/NiSi wires (0 μV/°C). The Seebeck coefficient (41.39 μV/°C) of the NiCr/NiSi thin-film thermocouple connected to copper wire is significantly higher than that of the thermocouple connected to copper wire (0 μV/°C). The problem of the Seebeck coefficient of the K-type thermocouple is analyzed by experimental data, which provides the relevant parameter basis for the use of the K-type thermocouple. The method has the advantages of simple equipment, convenient operation, accurate and reliable data, and provides a basis for the sensor to measure the temperature measurement.
Reference20 articles.
1. Development of multi-functional nano-paint for energy harvesting applications[J];Bohara,2018
2. T-type flexible thin film thermocouple response speed test and its application [J];Xong;Shanghai Measurement Testing,2023
3. Development of a Thermocouple for Thermal Conductivity and Insulation Surface Testing [J];Zhang;Metrology and test technology,2022