Abstract
Abstract
The noise characteristics of NACA0009 hydrofoil with tip clearance are discussed. Select SST k- ω Turbulence model and Schnerr Sauer cavitation model simulate tip leakage cavitation flow. The results show that the simulation results are in good agreement with the original records, and the tip clearance reduces the energy characteristics of the hydrofoil. With the expansion of tip clearance model, TLV and cavitation compressive strength gradually decrease. In addition, the study of far-field noise shows that the nonspecific curve of the total noise coefficient of far-field noise shows a disc shaped symmetric structure. Compared with the original hydrofoil, when the tip clearance is 20 mm, the far-field dipole noise value at 170 ° angle is reduced by 17.68%. Tip clearance reduces offline and far-field noise. Far field noise decreases with the increase of tip clearance model.
Subject
Computer Science Applications,History,Education
Reference8 articles.
1. Vortex suppression and flow pattern analysis of a hydrofoil with parallel grooves[J];Chen;Processes,2021
2. Cavitation behavior study in the pump mode of a reversible pump-turbine[J];Tao,2018
3. Investigation of the noise induced by unstable flow in a centrifugal pump[J];Lu;Energies,2020
4. Behavior of tip leakage flow behind an axial compressor rotor[J];Inoue;Journal of Engineering for Gas,1986
5. Tip leakage flow in axial compressors[J];Storer;Journal of Turbomachinery,1991