Quality control measurements for mobile X-ray unit through a solid state detector

Author:

Silva Gustavo Bernardes da,Mariotti Vinicius,Peixoto Matheus Silveira de Almeida,Pianoschi Thatiane,Alva-S´anchez Mirko S.

Abstract

Abstract The tests of quality control for equipments used in radiology departments are essential both functionality of the equipment and for accuracy dose in the patient. The mobile digital x-ray equipment has as one of its main benefits its mobility, which allows the carrying out of examinations in the patient’s bed that has certain physical limitations. It should be taken into account, however, that hospital beds were not normally designed with the necessary details to protect the radiological environment from where radiography procedures are performed. Therefore, the need for an efficient quality control of the equipment is justified, the preliminary measurements of the present work were based on ANVISA’s guide 453 from Brazil, regarding conventional radiography equipment. Thus, some quality control tests were determined using the solid state dosimeter. For the accomplishment of this study, the tests of tube voltage accuracy and reproducibility, half valuelayer (HVL) and effective energy, air kerma and air kerma rate were performed, with their associated errors calculated. The tests were performed with the aid of the black piranha apparatus to obtain the values of tension, dose and HVL. The obtained results from the performance of each test showed that all are in agreement withthe ANVISA’s guide 453 recommendation, and could be applied in a possible development of a quality control guide specific to the characteristics of a mobile radiograph.

Publisher

IOP Publishing

Subject

General Physics and Astronomy

Reference18 articles.

1. Development of a mini-mobile digital radiography system by using wireless smart devices;Jeong;J Digit Imaging,2014

2. A study of chest radiography with mobile X-ray units;Simpson;The British J. of Rad.,1998

3. Riscos ocupacionais e do público durante exames radiológicos em Unidades de Terapia Intensiva (UTIs) de um hospital público de Sergipe;Santos;Scientia Plena,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3