Abstract

Abstract Environmental radiation monitoring especially around nuclear facility is needed to ensure public protection and safety. An online radiation monitoring system which continuously detects the presence of radioactive material in the environmental is important system to quickly detects uncontrolled radioactive released to the air. In this study, a radiation detection device based-on NaI(Tl) scintillation detector as part of an online radiation monitoring system has been developed and tested. During field testing, radiation count rate, and operational condition parameters which are temperature and relative humidity was collected continuously for 3 months. Data was transferred every 10 seconds with average communication delay around 0.57 second. Total number of data points is 733,725 records, and the average count rate was 653.09 cpm (σ = 81.77). Measured temperature is between 18.9 °C and 44.3 °C, while relative humidity is between 19.4 %RH and 78.6 %RH. Experimental result shows that count rate has temperature dependence. Effect of temperature to the count rate was estimated using power equation, and then the equation is used to correct the measurement data. After correction, several peaks which indicates the presence of radioactive material other than background radiation can be identified easily. In the future, further development such as radionuclide identification feature can be added to the prototype.

Publisher

IOP Publishing

Subject

General Physics and Astronomy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Review and design of muon detector for monitoring the building material crack for the earthquake-resistant house in Indonesia;PROCEEDINGS OF THE 9TH INTERNATIONAL SYMPOSIUM ON INNOVATIVE BIOPRODUCTION INDONESIA ON BIOTECHNOLOGY AND BIOENGINEERING 2022: Strengthening Bioeconomy through Applied Biotechnology, Bioengineering, and Biodiversity;2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3