Abstract
Abstract
Two punching shear failure tests of two-way concrete slab reinforced by CFRP grid and HRB 400 steel were studied in this paper. The reinforcement ratio of slab reinforced with CFRP grid and HRB400 is 0.33% and 0.37 respectively. The upper and lower surfaces of the concrete slab’s tensile and compressive strains, the reinforcement strains, the load deflection of the slabs, and the applied load value were analyzed. The results show that under approximately the same reinforcement ratio, the concrete slab reinforced with CFRP grid has higher bearing capacity. Both slab failure formed with punching cones, the punching cone angle of CFRP grid slab is 24.1°, which is far less than 38° for reinforced concrete slabs. The tests results indicated that there is a cooperative between longitudinal and transverse limb of CFRP grid.