Enhancing process efficiency through improved temperature measurement: the EMPRESS projects

Author:

Pearce J V,Edler F,Fateev A,Sutton G,Andreu A,Machin G

Abstract

AbstractEMPRESS 2 is a European project to enhance the efficiency of high value manufacturing processes by improving temperature measurement and control capability. This project seeks to address four contemporary thermometry challenges in this sector, and new developments from this and its predecessor project, EMPRESS, will be described:• Below 1000°C many industrial processes require reliable surface thermometry e.g. welding, coating, forging and forming. Conventional non-contact surface thermometry techniques e.g. thermal imaging are prone to large errors (tens of degrees) due to reflected thermal radiation and unknown emissivity. Contact thermometry approaches are prone to similarly large errors. Traceable imaging phosphor thermometry is being developed to overcome these difficulties, and is being combined with quantitative thermography to determine emissivity for thermometry over wide fields of view.• Above 1300°C sensor drift is a significant unaddressed issue for casting, forging and heat treatment, causing large errors. There is a need for more stable sensors and standardisation of at least one new thermocouple type to fill the gap from 1300°C to 1800°C. This is being addressed through improved Pt-Rh thermocouples and optimisation of double-walled mineral insulated, metal sheathed thermocouples by mitigating insulation breakdown and drift effects.• Combustion temperature measurement is very challenging and traceability is almost non-existent; for example, thermocouple measurements of flame temperatures can be in error by hundreds of degrees. A ‘standard flame’ that can be transported to users’ sites has been developed, and is being deployed in several high value manufacturing and industrial applications to a) demonstrate the possibility of reducing flame temperature uncertainties by at least an order of magnitude and b) for the first time to demonstrate in-situ traceability to the International Temperature Scale of 1990 (ITS-90).• Many processes are not amenable to any conventional thermometry techniques due to inaccessibility, ionising radiation, electromagnetic interference, and contamination; here methods based on optical fibres are ideal but there are no traceable calibration techniques for such sensors currently available. A suite of different fibre-optic thermometers and calibration techniques is being developed to address this. In some cases (ionising radiation) darkening of the fibre is a problem, and this is being overcome by the development of novel thermometry approaches based on practical ‘hollow core’ fibres.

Publisher

IOP Publishing

Subject

Computer Science Applications,History,Education

Reference47 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3