Abstract
Abstract
The high content of COD has always been a difficult problem for the efficient treatment of brewing wastewater. Pretreatment of brewing wastewater to reduce the content of COD was considered as a better solution. In this paper, ozone oxidation technology was used to pretreat brewing wastewater to preliminarily reduce the COD content, so as to provide beneficial conditions for further efficient treatment. The results showed that the reaction temperature (A), ozone intake (B), pH value of reaction solution (C) and reaction time (D) were the main factors affecting the removal of COD from brewing wastewater by ozone oxidation. Combined with the orthogonal test method, the optimum process conditions were A2B3C2D2. It was that the reaction temperature was 50 °C, the ozone intake flow was 7 L/min, the pH value of reaction solution was 7 and the reaction time was 1 h, which made the removal rate of COD reach 40.5%, and realized the goal of pre-removal of COD in brewing wastewater.
Subject
General Physics and Astronomy
Reference9 articles.
1. Anaerobic treatment of domestic wastewater in a membrane-coupled expended granular sludge bed (EGSB) reactor under moderate to low temperature [J];Chu;Process Biochemistry,2005
2. Ozone oxidation treatment process for Baijiu wastewater nanofiltration concentrate [J];Cui;Water treatment technology,2013
3. Study on reducing chemical oxygen demand (COD) in Baijiu wastewater. [J];Lan;Shandong chemical industry,2020
4. Experimental study on advanced treatment of alcohol wastewater by Fenton oxidation process [J];Pan;China water supply and drainage,2010