Influence of Lightning Characteristics on Back Flashover in Extra High Voltage Transmission Line: A case study

Author:

Hardi Surya,Mirza F,Bukit Ferry R A,Rohana

Abstract

Abstract Lightning is one of the primary sources that cause failure on over head transmission system. It can lead to the transmission line insulator to be over voltage. Commonly, transmissions lines are equipped with ground wire and consist of one or two ground wire which it is depending on tower construction. Over voltage on the transmission line can occur in two ways viz., direct lightning strike on phase line and ground wire produce propagating wave to both sides the phase line and result in damage on insulator. Direct lightning stroke on ground wire or the tower structure of transmission can cause phenomenon back flashover (BFO) on insulator. The lightning current characteristic is distinguished in lightning maximum current and steepness of lightning current. This paper discusses influence of in different lightning characteristics on BFO in extra high voltage transmission line in simulation using ATP draw. The lightning surge currents of IEC and VDE standards were injected to the ground wire and phase lines. As the implementation, this paper used the data of extra high voltage transmission line of 275 kV, Galang - Binjai, North Sumatra Province, Indonesia.

Publisher

IOP Publishing

Subject

General Physics and Astronomy

Reference11 articles.

1. Lightning Performance of 275 kV Transmission line;Bhattarai,2009

2. Tropical Lightning Current Parameter and Protection of Transmission Line;Zoro;International Journal on Electrical engineering and Informatics,2019

3. The Effect of Lightning Impulse Characteristics and line arrester to the lightning protection performance on 150 kV overhead line: ATP-EMTP Computational Approach;Murdiya;Journal of Mechatronics, Electrical Power and Vehicular Technology,2019

4. Modeling of Overhead Transmission lines for Lightning Over voltage Calculation;Martinez;Revista chilena de ingeniera,2010

5. Photopumped laser diode continuous wave for optical gain determination of Nd: YVO4 and Nd: YAG crystal medium;Rajagukguk;Journal of Metals, Materials and Minerals.,2019

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Flashover pattern analysis for 275 kV double circuit transmission lines during direct lightning strikes;Electric Power Systems Research;2024-03

2. Comparative Analysis of The Effective Grounding System on External LPS Modeling in PV Fields;2023 7th International Conference on Electrical, Telecommunication and Computer Engineering (ELTICOM);2023-12-13

3. Modeling of Electric Potential Assessment for Substation Grounding Grid Under Lightning Strikes Using LabVIEW;2023 International Conference on Converging Technology in Electrical and Information Engineering (ICCTEIE);2023-10-25

4. A protocol for selecting viable transmission line arrester for optimal lightning protection;Electric Power Systems Research;2023-08

5. Transient characteristic of transmission line and tower footing grounding due to lightning strike;THE 4TH TALENTA CONFERENCE ON ENGINEERING, SCIENCE AND TECHNOLOGY (CEST)-2021: Sustainable Infrastructure and Industry in the New Normal Era;2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3