Author:
Asadchiy A V,Soldatov A I,Soldatov A A,Kim O H
Abstract
Abstract
The block diagram of the monitoring device is presented. The operation principle of the monitoring device is described. The main units affecting the quality of the monitored signal reconstruction are shown. The analysis of the differentiating device and the voltage-controlled generator is carried out. The main characteristics of the differentiating device and the voltage-controlled oscillator are given and the quality of signal reconstruction is evaluated when their parameters change. The requirements for choosing the optimal value of the derivative time constant and the frequency range of the voltage-controlled generator are specified. A calculation example of the required RAM for recording and reconstruction of the monitored signal is shown.
Subject
General Physics and Astronomy
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献