Author:
Chen Fan,Chen Long,Lian Pengfei,Liu Dapeng,Tao Shuai,Kong Zebin
Abstract
Abstract
Accurate measurement of junction temperature can avoid thermal failure of diode. During aging test, junction temperature should be indirectly calculated by testing its thermal resistance. In this paper, junction-to-case thermal resistance (Rthjc) of XX diode is tested by T3ster based on transient dual interface method. Its Rthjc is about 1.23K/W at 25°C and contains PN junction thermal resistance, metal shell thermal resistance and Sn-based solder thermal resistance, respectively. These three types of thermal resistance decrease in order. Effect of shell temperature on junction temperature and Rthjc is then discussed. As shell temperature increases, temperature variation of PN junction before and after heating and corresponding thermal resistance Rthjc both increase.
Subject
General Physics and Astronomy