Author:
Abrar Usama,Shi Liu,Jaffri Nasif R.,Li Qin,Omar Mian W.,Sindhu Hassan R.
Abstract
Abstract
The precise and accurate measurement of flow rate in the batch flow of the solid particles is of primary importance in many process industries for the improvement of the efficiency of the system. Many techniques developed for the measurement of mass flow rate. The capacitive sensors has a significance of being non-invasive, higher accuracy and low cost for mass flow measurement despite the fact that many factors adversely affect the performance- including non-uniform flow, multiphase flow, temperature, pressure, and moisture in the solid particles. This paper covers preliminary investigations of the offline estimation of mass flow concentration based upon the calibration of capacitance electrodes to quantify the mass of dielectric as a function of capacitance variation between the electrodes.
Subject
General Physics and Astronomy
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献