We present the development of the FBCM23 ASIC designed for the Phase-II upgrade of the
Fast Beam Condition Monitoring (FBCM) system built at the CMS experiment which will replace the
present luminometer based on the BCM1F ASIC [1]. The FBCM system should
provide reliable luminosity measurement with 1 ns time resolution enabling the detection of
beam-induced background. The FBCM23 ASIC comprises 6 channels of the fast front-end amplifier
working in transimpedance configuration, booster amplifier, and leading edge
discriminator. The complete processing chain provides an overall shaping function equivalent to
the CR-RC3 filter. The paper will show the optimization of the design, overall
architecture, and the detailed implementation in a CMOS 65 nm process as well as preliminary
electrical performance.