Measured and GATE predicted PET-image-based activity range verification for carbon therapy: a phantom study

Author:

Pei C.X.,Zhang X.L.,Yan J.W.,Kong J.,Wang C.X.,Hu M.C.,Liang G.Y.,Duan L.M.,Hu Z.G.,Xu H.S.,Yin Y.Z.,Chen J.D.

Abstract

Abstract In-beam PET is one of the imaging-based methods for monitoring carbon therapy by reconstruction of positron-emitters produced by incident particles. The accurate Monte Carlo simulation is necessary for range verification and therapeutic dose monitoring by means of the in-beam PET. GATE is capable of performing in-beam PET imaging but very few studies assess the accuracy of activity range measured from PET imaging with GATE simulated results. In this work, we present both experimental and GATE simulation studies of in-beam PET imaging of a phantom, which is irradiated by carbon ion beam, for range verification. The experiment data is acquired at Wuwei Heavy Ion Cancer Treatment Center in Gansu, China, with a dual-head plate PET prototype. The PET prototype consists of 2 panels, each arranged in 2 × 2 matrix. Each detector block is composed of 20 × 20 LYSO crystal array coupled with the position-sensitive photomultiplier tube (HAMAMATSU H8500). A homogeneous plastic phantom is irradiated with monoenergetic 131.05 MeV and 190.19 MeV 12C ion pencil beams. The irradiation and full response of PET prototype are simulated with GATE macros. A novel mathematical model is established, which is capable of calculating and revealing the variation of the positron activity. Our focus is on the reconstructed activity ranges obtained by the experimental measurement and GATE MC prediction combined with the positron activity distribution calculation mathematical model. Results show that the reconstructed activity distribution of experimental data and GATE MC prediction are in good agreement. The measured and simulated 1D activity peak and falling edge positions are within 1.0 mm in all cases. The 20%, 50% and 80% PET peak positions predicted by GATE are close to measurements. These results indicated that it is feasible to assess the accuracy of activity range measured from the dual-head plate PET system with the modeled GATE hadron-PET simulation.

Publisher

IOP Publishing

Subject

Mathematical Physics,Instrumentation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3