Author:
Scharenberg L.,Bortfeldt J.,Brunbauer F.,Christensen M.J.,Desch K.,Flöthner K.,Garcia F.,Janssens D.,Kaminski J.,Lisowska M.,Lupberger M.,Muller H.,Oliveri E.,Orlandini G.,Pfeiffer D.,Ropelewski L.,Rusu A.,Samarati J.,Schwäbig P.,van Stenis M.,Veenhof R.
Abstract
Abstract
The RD51 collaboration developed the Scalable Readout System (SRS) as part of its R&D activities on Micro-Pattern Gaseous Detectors. This common multi-purpose readout system allows to read out small R&D detectors (0.2k channels) up to mid-sized experiments with multiple detectors (2.5k to 5k channels). To cope with increased demands on detectors, electronics and readout speed, a new front-end ASIC—the VMM3a—was integrated into the SRS. This led to the development of a scalable, self-triggered high-rate readout system that provides energy, space and time information of the interacting particles at the same time.
Subject
Mathematical Physics,Instrumentation
Reference16 articles.
1. Development of the scalable readout system for micro-pattern gas detectors and other applications;Martoiu;JINST,2013
2. The APV25 0.25 μm CMOS readout chip for the CMS tracker;Raymond;IEEE Nucl. Sci. Symp. Conf. Rec.,2000
3. The VMM3a ASIC;de Geronimo;IEEE Trans. Nucl. Sci.,2022
4. Rate-capability of the VMM3a front-end in the RD51 scalable readout system;Pfeiffer;Nucl. Instrum. Meth. A,2022