First characterization results of ARCADIA FD-MAPS after X-ray irradiation

Author:

Neubüser C.,Corradino T.,Dalla Betta G.-F.,Mattiazzo S.,Pancheri L.

Abstract

Abstract The ARCADIA collaboration is developing fully-depleted (FD) Monolithic Active Pixel Sensors (MAPS) in a 110 nm CMOS process in collaboration with LFoundry. The sensor design incorporates an n+ collection node within a n-type epi-layer on top of a high-resistivity n-type substrate and p+ backside. Thus, the pn-junction sits on the backside and through an applied backside bias, the full substrate gets depleted. The targeted applications of this technology range from future high energy physics experiments to space applications, and medical and industrial scanners. Together, these applications set the minimum requirements on the detector: data collection at hit rates of (10–100) MHz/cm2, full signal processing within (1–10) μs, maximum power consumption (5–20) mW/cm2 and radiation tolerances of up to 3.4 Mrad or 6.2 × 1012 1 MeV neutron equivalent fluence. In order to proof the performance of the technology, a demonstrator chip of 512 × 512 pixels with 25 μm pitch was designed and fabricated in a first engineering run in 2021, together with additional test structures of pixel and strip arrays with different pitches and sensor geometries. The production run has produced functional passive and active pixel matrices. Earlier studies have shown that positive oxide charges and traps at the Si-SiO2 interface, introduced by ionising radiation, affect the depletion region around the collection electrode, increasing the pixel capacitance. By varying the gap size between collection node and pwells, the geometry can be optimised to keep the capacitance low also after irradiation. To study the performance after irradiation, of the optimised diode designs, the passive pixel matrices were irradiated with doses up to 10 Mrad (SiO2) using a X-ray tube with a Tungsten anode. The measurements are complemented by TCAD simulations. The maximum capacitance increase after irradiation was found to reach 6 and 12 fF/pixel for pixel pitches of 25 and 50 μm, respectively. The relative capacitance increase after irradiation has hereby been found to reach up to 250% after a dose of 10 Mrad.

Publisher

IOP Publishing

Subject

Mathematical Physics,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3