METU-DBL: a cost effective proton irradiation facility

Author:

Karadöller E.,Uzun Duran S.,Kılıç U.,Hashmani R.K.,Demirköz M.B.,Efthymiopoulos I.,Can A.B.,Çakmakoğlu S.,Muçogllava B.,Kayaalp A.,Zorlu C.

Abstract

Abstract The Middle East Technical University Defocusing Beamline (METU-DBL) is designed to deliver protons with selectable kinetic energies between 15–30 MeV, and proton flux between 106–1010 protons/cm2/s, on a maximum 21.55 to 15.40 cm target region with a beam uniformity within ±6%, in accordance with the ESA ESCC No. 25100 specification for single event effects (SEEs) tests in the low energy range. The achieved high proton fluences, allow users to test space-grade materials; electronic circuits, ASICs, FPGAs, optical lenses, structural elements, and coating layers for LEO, GEO, and interplanetary missions. The total received dose on the Device-Under-Test (DUT) from secondary particles created during proton-material interactions at the first beam collimator and the beam dump never exceed 0.1% of the dose from primary protons. The METU-DBL is equiped with several measurement stations and services to the user teams. A secondary measurement station in a rotating drum that can hold multiple samples has been constructed next to the first collimator which provides neutrons for transmission experiments. At the target region, a robotic table is located, which provides mechanical and electrical mounting points to the samples and allows multiple samples to be tested in a row. A modular vacuum box can also be attached on the robotic table for any test that may require a vacuum environment. Power rails on the robotic table provide various outputs for the DUT. For the data acquisition, high-speed networking and a modular industrial PC are available at the target station. The design of the METU-DBL control software enables test users to integrate and optimize the data acquisition and controlling of the DUT. The beam properties at the target region are measured with the diamond, Timepix3, and fiber scintillator detectors mounted on the robotic table. With diamond and Timepix3 detectors, measurements are taken from the five different points (center and the four corners) of the test area to measure the proton flux and ensure that it is uniform across the full test area. Fiber scintillators on both axes (X and Y) scan the target area to cross-check the beam profile's uniformity. Secondary doses during the irradiation are measured by a Geiger-Müller tube sensitive to electrons and gammas above 0.1 MeV and by a neutron detector located at the entrance of the R&D room. The room cools down relatively fast after any irradiation (<1 hour). Accurate linear energy deposition rates and absorbed doses on the samples are calculated using MCNP6, FLUKA and Geant4 Monte Carlo simulations. Alanine dosimetry measurements that are calibrated against these simulations are also used to estimate the absorbed dose on the sample.

Publisher

IOP Publishing

Subject

Mathematical Physics,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3