Kopsalis I.,Allport P.,Bach E.,Bhardwaj A.,Chisholm A.,Cindro V.,Fadeyev V.,Federicova P.,Fernandez-Tejero J.,Fleta C.,Freeman P.,George W.,Glover J.,Gonella L.,Hara K.,Hirose S.,Hunter A.,Ishii T.,Knight T.,Kroll J.,Kvasnicka J.,Lacasta C.,Latonova V.,Lomas J.,Mandić I.,Mikestikova M.,Nakamura K.,Orr R.S.,Pyatt S.,Sato K.,Solaz C.,Soldevila U.,Thomas J.,Ullan M.,Unno Y.
Abstract
Abstract
The successful pre-production delivery of strip sensors for the new Inner Tracker (ITk)
for the upgraded ATLAS detector at the High Luminosity LHC (HL-LHC) at CERN was completed and
based on their performance full production has commenced. The overall delivery period is
anticipated to last 4 years to complete the approximately 22000 sensors required for the ITk. For
Quality Assurance (QA), a number of test structures designed by the collaboration, along with a
large area diode and miniature version of the main sensor, are produced in every wafer by the
foundry Hamamatsu Photonics K.K (HPK). As well as Quality Control (QC) checks on every main
sensor, samples of the QA pieces from each delivery batch are tested both before and after
irradiation with results after exposure to neutrons, gammas or protons to fluences and doses
corresponding to those anticipated after operation at the HL-LHC to roughly 1.5 times the ultimate
integrated luminosity of 4000 fb-1. In this paper the procedures are presented and the
studies carried out to establish that the seven ITk QA Strip Sensor irradiation and test sites
meet all the requirements to support this very extensive programme throughout the strip sensor
production phase for the ITk project.