Author:
Levinton F.M.,Reichert H.,De Bock M.
Abstract
Abstract
We provide an overview of ITER beam aided diagnostics, including the motional Stark effect (MSE) and charge exchange recombination spectroscopy (CXRS). ITER presents several unique challenges to plasma diagnostics in general and beam-aided diagnostics in particular. The large size, long pulse, and DT operation drives much of the diagnostic design. This in turn has driven a significant R&D effort concerning the maintenance of plasma facing mirrors with sufficient reflectivity to maintain the utility of the diagnostic. In the case of MSE a new approach utilizing spectral splitting will be pursued instead of the conventional polarimetry approach due to the difficulty of maintaining and calibrating the polarizations properties of the plasma facing mirror.
Subject
Mathematical Physics,Instrumentation
Reference18 articles.
1. Innovations in technology and science R&D for ITER;Campbell;J. Fusion Energy,2019
2. Overview of the design of the ITER heating neutral beam injectors;Hemsworth;New J. Phys.,2017
3. Diagnostic neutral beam for ITER-concept to engineering;Chakraborty;IEEE Trans. Plasma Sci.,2010
4. The core-plasma CXRS diagnostic for ITER: an introduction to the current design;Mertens;J. Fusion Energy,2019
5. Cross sections for collision processes of hydrogen atoms with electrons, protons and multiply charged ions;Janev,1993