Development and verification of a Geant4 model of the electron beam mode in a clinical linear accelerator

Author:

Miloichikova I.,Bulavskaya A.,Bushmina E.,Dusaev R.,Gargioni E.,Gavrikov B.,Grigorieva A.,Stuchebrov S.

Abstract

Abstract At present, a significant number of studies are focused on the development of novel methodologies for the fabrication of dosimetry phantoms. One of these methods is to produce heterogeneous samples by 3D printing. In order to select the most appropriate parameters for such products, it is necessary to conduct numerical simulations. In this work, we developed the model of a beam-forming system using a medical linear accelerator as a reference. This model was used to determine simulation parameters and corresponding dose distributions of an electron beam with nominal energies of 6, 12, and 15 MeV in a homogeneous water phantom. These parameters were, in fact, adapted to provide maximum agreement between simulated distributions and those experimentally obtained with the clinical linear accelerator. The beam simulation was performed using the Geant4 Monte Carlo toolkit. The simulation geometry of the accelerator treatment head includes scattering foil and a flattening filter, which are designed for electron beam broadening. Additionally, the beam-forming system was incorporated to collimate the beam to the required size. A metal applicator was included to reduce the contribution of electron scattering in air. The main simulation parameters were iteratively tuned by comparing simulation results with experimentally obtained data. It is shown that the simulated percentage depth dose and transverse profiles for electron beams in water phantom are in good agreement with the experimental data obtained with a cylindrical ionization chamber. This demonstrates that the methodology employed in the development of the numerical model of the medical linear accelerator is vendor-independent, readily implementable, and allows for rapid calculations. Furthermore, the model can be applied for a variety of purposes, including the selection of parameters for the fabrication of heterogeneous dosimetry phantoms.

Publisher

IOP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3