Author:
Dey T.,Mukhopadhyay S.,Chattopadhyay S.
Abstract
Abstract
The working of a resistive plate chamber depends on the electric field applied inside the gas gap. The strength of this electric field inside the gas gap depends on parameters like electrode thickness, permittivity, and gas gap, among others. The applied electric field can get significantly modified by the space charge effect. This can be a major concern while working in high rate particle physics experiments. Accumulation of space charge generated due to consecutive avalanches can distort the applied field. During this investigation, we have observed that the strength of this perturbation in the electric field is a function of the amount of charge, electrode thickness, permittivity, and gas gap.
In this paper, we have studied the dependence of the applied field on parameters linked to RPC fabrication mentioned above. In addition, we have used the method of image to calculate the additional polarisation field due to space charge for a basic five layers of the geometry of an RPC. The variation of the perturbation in the electric field with the same three parameters electrode thickness, permittivity, gas gap has also been discussed.
Subject
Mathematical Physics,Instrumentation