Numerical and experimental investigations of a microwave interferometer for the negative ion source SPIDER

Author:

Agnello R.,Cavazzana R.,Furno I.,Jacquier R.,Pasqualotto R.,Sartori E.,Serianni G.

Abstract

Abstract The electron density close to the extraction grids and the co-extracted electrons represent a crucial issue when operating negative ion sources for fusion reactors. An excessive electron density in the plasma expansion region can indeed inhibit the negative ion production and introduce potentially harmful electrons in the accelerator. Among the set of plasma and beam diagnostics proposed for SPIDER upgrade, a heterodyne microwave (mw) interferometer at 100 GHz is currently being explored as a possibility to measure electron density in the plasma extraction region. The major issue in applying this technique in SPIDER is the poor accessibility of the probing microwave beam through the source metal walls and the long distance of 4 m at which mw modules should be located outside the vacuum vessel. Numerical investigations in a full-scale geometry showed that the power transmitted through the plasma source apertures was above the signal-to-noise ratio threshold for the microwave module sensitivity. An experimental proof-of-principle of the setup to assess the possibility of signal phase detection was then performed. The microwave system was tested on an experimental full-scale test-bench mimicking SPIDER viewports accessibility constraints, including the presence of a SPIDER-like plasma. The outcome of first tests revealed that, despite the geometrical constraints, in certain conditions, the phase detection, and, therefore, electron density measurements are possible. The main issue arises from decoupling the one-pass signal from spurious multipaths generated by mw beam reflections, requiring signal cross correlation analysis. These preliminary tests demonstrate that despite the 4 m distance between the mw modules and the presence of metal walls, plasma density measurement is possible when the 80 mm diameter ports are available. In this contribution, we discuss the numerical simulations, the preliminary experimental tests and suggest design upgrades of the interferometric setup to enhance signal transmission.

Publisher

IOP Publishing

Subject

Mathematical Physics,Instrumentation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Improvement of SPIDER diagnostic systems;Fusion Engineering and Design;2023-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3