Abstract
The light yield, the time resolution and the efficiency of
different types of scintillating tiles with direct Silicon
Photomultiplier readout and instrumented with a customised front-end
electronics have been measured at the Beam Test Facility of
Laboratori Nazionali di Frascati and several test stands. The
results obtained on minimum ionising particles with different
detector configurations are presented. A time resolution of the
order of 300 ps, a light yield of more than 230 photo-electrons, and
an efficiency better than 99.8% are obtained with
∼ 225 cm2 large area tiles. This technology is suitable
for a wide range of applications in high-energy physics, in
particular for large area muon and timing detectors.