Abstract
Abstract
The mass production of the first stage of HEPS (High Energy
Photon Source) is approaching its final stage. 6 CPMUs (cryogenic
permanent magnet undulators) have been manufactured, with four
successfully finalizing the tuning of the magnetic field. To ensure
radiation performance, HEPS's CPMUs enforce stringent phase error
protocols. Moreover, the contraction properties at cryogenic
temperature lead to a decrease in phase error after cooling. In the
process of CPMU commissioning, a technique for forecasting the
change of magnetic errors from room to cryogenic temperature was
discovered and studied, as will be demonstrated in this paper.
Reference9 articles.
1. The HEPS project;Jiao;J. Synchrotron Radiat.,2018
2. Development of a PrFeB Cryogenic Permanent Magnet Undulator (CPMU) Prototype at IHEP;Lu,2017
3. Field Error Correction Considerations of Cryogenic Permanent Magnet Undulator (CPMU) for High Energy Photon Source Test Facility (HEPS-TF)*;Yang,2016
4. Four-row APPLE-Knot undulator mechanical design and test piece studies for High Energy Photon Source;Huang;Journal of Instrumentation,2022