Near-field coded-mask technique and its potential for proton therapy monitoring

Author:

Hetzel RonjaORCID,Urbanevych VitaliiORCID,Bolke AndreasORCID,Kasper Jonas,Kercz MonikaORCID,Kołodziej MagdalenaORCID,Magiera AndrzejORCID,Mueller FlorianORCID,Müller SaraORCID,Rafecas MagdalenaORCID,Rusiecka KatarzynaORCID,Schug DavidORCID,Schulz VolkmarORCID,Stahl AchimORCID,Weissler BjoernORCID,Wong Ming-LiangORCID,Wrońska AleksandraORCID

Abstract

Abstract Objective. Prompt-gamma imaging encompasses several approaches to the online monitoring of the beam range or deposited dose distribution in proton therapy. We test one of the imaging techniques - a coded mask approach - both experimentally and via simulations. Approach. Two imaging setups have been investigated experimentally. Each of them comprised a structured tungsten collimator in the form of a modified uniformly redundant array mask and a LYSO:Ce scintillation detector of fine granularity. The setups differed in detector dimensions and operation mode (1D or 2D imaging). A series of measurements with radioactive sources have been conducted, testing the performance of the setups for near-field gamma imaging. Additionally, Monte Carlo simulations of a larger setup of the same type were conducted, investigating its performance with a realistic gamma source distribution occurring during proton therapy. Main results. The images of point-like sources reconstructed from two small-scale prototypes’ data using the maximum-likelihood expectation maximisation algorithm constitute the experimental proof of principle for the near-field coded-mask imaging modality, both in the 1D and the 2D mode. Their precision allowed us to calibrate out certain systematic offsets appearing due to the limited alignment accuracy of setup elements. The simulation of the full-scale setup yielded a mean distal falloff retrieval precision of 0.72 mm in the studies for beam energy range 89.5–107.9 MeV and with 1 × 108 protons (a typical number for distal spots). The implemented algorithm of image reconstruction is relatively fast—a typical procedure needs several seconds. Significance. Coded-mask imaging appears a valid option for proton therapy monitoring. The results of simulations let us conclude that the proposed full-scale setup is competitive with the knife-edge-shaped and the multi-parallel slit cameras investigated by other groups.

Funder

Deutscher Akademischer Austauschdienst

Horizon 2020 Framework Programme

Bundesministerium für Bildung und Forschung

Deutsche Forschungsgemeinschaft

Narodowa Agencja Wymiany Akademickiej

Narodowe Centrum Nauki

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3