Development of a two-layer dense-pixel LYSO Compton camera prototype for prompt gamma imaging

Author:

Yao ZhiyangORCID,Xiao Yongshun,Dong Minghao,Deng Heng

Abstract

Abstract Objective. Lutetium–yttrium orthosilicate (LYSO)-based Compton camera (CC) has been proposed for prompt gamma imaging due to its high detection efficiency and position resolution. However, very few LYSO CC prototypes have been built and used for practical evaluation. In this study, we built a lightweight dense-pixel silicon photomultiplier-based two-layer LYSO CC prototype for future prompt gamma imaging. Approach. We attempt the first-ever effort to use the double-encoding with the thick light guide and coding circuit structure for 46 × 46 dense-pixel LYSO detectors construction and use pixel segmentation based on centroid mapping to obtain 4232 spectral calibrations. We also present a framework for list-mode projection data acquisition based on the decoding of the time series data obtained by data acquisition card in this study. Finally, the standard source calibration, ring-like 22Na source with non-uniform intensity, and mixed point-like source with a wide energy spectrum experiments were implemented to evaluate the resolution metrics and imaging performance of the prototype. Main results. The lateral position resolution of the prototype was 1 mm, and the maximum measurement deviation is 2.5 mm and 5 mm in the depth direction for the scatterer and absorber, respectively. In the experiments, the measured energy resolution was 9.63% @ 1.33 MeV for the scatterer and 10.8% @ 1.33 MeV for the absorber. And the detection efficiency of the prototype for a spherical 60Co source with a diameter of 2.8 mm at 10 cm far was 5.7 × 10−3 @ 1.33 MeV and the full width at half maximum of the reconstruction was 5.5 mm. Besides, the spatial position offset within 2 mm of the radioactive source at 10 cm can be distinguished. Signification. The developed two-layer dense-pixel LYSO CC contributes to incorporating Compton imaging techniques for prompt gamma detection and multiple energy sources into nuclear medical imaging.

Funder

Beijing Municipal Nature Science Foundation

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Accurate Range Shift Verification by Using a Dual-View LYSO-LaBr3 Compton Camera Prototype during Proton Beam Irradiation;2023 IEEE Nuclear Science Symposium, Medical Imaging Conference and International Symposium on Room-Temperature Semiconductor Detectors (NSS MIC RTSD);2023-11-04

2. Development and preliminary results of a large-pixel two-layer LaBr3 Compton camera prototype;Nuclear Science and Techniques;2023-08

3. Dose reconstruction with Compton camera during proton therapy via subset-driven origin ensemble and double evolutionary algorithm;Nuclear Science and Techniques;2023-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3