Abstract
Abstract
Objective. To develop a simultaneous positron emission tomography-Optical (OPET) breast imaging dual-head PET subsystem, called DH-Mammo PET, for accurate, early diagnosis and efficacy assessment of breast cancer with high resolution and sensitivity. Approach. We developed a breast-dedicated PET based on LYSO crystal, silicon photomultiplier array and multi-voltage threshold sampling technique. It consists of two detector heads, each with a detection area of 216 mm × 145.5 mm. The distance between the detector heads is fixed at 120 mm. In order to extract coincidences and correct data, GPU-based software coincidence processing, random, scatter, normalization, gap-filling and attenuation corrections were applied in turn. The images were reconstructed using maximum likelihood expectation maximization with depth of interaction (DOI) modeling. The performance of DH-Mammo PET was evaluated referring to NEMA NU 4–2008, NU 2–2007 and Chinese industry recommended standard YY/T 1835–2022. Besides, several clinical patient images of DH-Mammo PET were compared with those of a whole-body PET/CT. Main results. The energy resolution was 14.5%, and time resolution was < 1.31 ns. Indicated by the 22Na point source imaging, its spatial resolution was 2.60 mm (5.40 mm), 1.00 mm (1.04 mm), and 0.96 mm (0.93 mm) in the X, Y and Z directions, respectively, using the system response matrix with (without) DOI modeling. Indicated by the Derenzo phantom imaging, the spatial resolution was ∼3.0 mm, <1.2 mm, and <1.2 mm in the X, Y and Z directions. The system sensitivity was 6.87%, 4.89% and 3.37% with an energy window of 100–800, 250–750 and 350–650 keV, respectively. The scatter fraction was 26.43%, and the peak NECR was 162.6 kcps at 24.1 MBq for the modified rat-like phantom. As for the recovery coefficients, they ranged from 0.15 to 1.04 for rods between 1 and 5 mm obtained with a NEMA image quality phantom. The spill-over ratio for the air-filled and water-filled chamber was 0.05 and 0.11, respectively. DH-Mammo PET can provide more image details in clinical experiments and fulfil a fast scan with 60–120 s acquisition time. Significance. Good spatial resolution and high sensitivity of DH-Mammo PET would enable fast and accurate PET imaging of the breast. Besides, combining the DH-Mammo PET with the diffuse optical tomography would make full use of tumor metabolic imaging and tissue endogenous optical imaging, which would improve the accuracy of early clinical diagnosis of small lesions of breast cancers.
Funder
Fundamental Research Funds for the Central Universities
National Key Research and Development Program of China
CAS Key Technology Talent Program
CAS Youth Innovation Promotion Association
Natural Science Foundation of Hebei Province
Natural Science Foundation of Shaanxi Province
National Natural Science Foundation of China
Subject
Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Reference56 articles.
1. Influence of statistical fluctuation on reproducibility and accuracy of SUVmax and SUVpeak: a phantom study;Akamatsu;J. Nucl. Med. Technol.,2015
2. Effects of noise, image resolution, and ROI definition on the accuracy of standard uptake values: a simulation study;Boellaard;J. Nucl. Med.,2004
3. Initial characterization of a dedicated breast PET/CT scanner during human imaging;Bowen;J. Nucl. Med.,2009
4. Correction methods for random coincidences in fully 3D whole-body PET: impact on data and image quality;Brasse;J. Nucl. Med.,2005
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献