Deformable image registration of the treatment planning CT with proton radiographies in perspective of adaptive proton therapy

Author:

Palaniappan Prasannakumar,Meyer SebastianORCID,Kamp Florian,Belka Claus,Riboldi Marco,Parodi Katia,Gianoli Chiara

Abstract

Abstract The purpose of this work is to investigate the potentiality of using a limited number of in-room proton radiographies to compensate anatomical changes in adaptive proton therapy. The treatment planning CT is adapted to the treatment delivery scenario relying on 2D-3D deformable image registration (DIR). The proton radiographies, expressed in water equivalent thickness (WET) are simulated for both list-mode and integration-mode detector configurations in pencil beam scanning. Geometrical and analytical simulations of an anthropomorphic phantom in the presence of anatomical changes due to breathing are adopted. A Monte Carlo simulation of proton radiographies based on a clinical CT image in the presence of artificial anatomical changes is also considered. The accuracy of the 2D-3D DIR, calculated as root mean square error, strongly depends on the considered anatomical changes and is considered adequate for promising adaptive proton therapy when comparable to the accuracy of conventional 3D-3D DIR. In geometrical simulation, this is achieved with a minimum of eight/nine radiographies (more than 90% accuracy). Negligible improvement (sim1%) is obtained with the use of 180 radiographies. Comparing different detector configurations, superior accuracy is obtained with list-mode than integration-mode max (WET with maximum occurrence) and mean (average WET weighted by occurrences). Moreover, integration-mode max performs better than integration-mode mean. Results are minimally affected by proton statistics. In analytical simulation, the anatomical changes are approximately compensated (about 60%–70% accuracy) with two proton radiographies and minor improvement is observed with nine proton radiographies. In clinical data, two proton radiographies from list-mode have demonstrated better performance than nine from integration-mode (more than 100% and about 50%–70% accuracy, respectively), even avoiding the finer grid spacing of the last numerical optimization stage. In conclusion, the choice of detector configuration as well as the amount and complexity of the considered anatomical changes determine the minimum number of radiographies to be used.

Funder

Deutsche Forschungsgemeinschaft

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3