Impact of and interplay between proton arc therapy and range uncertainties in proton therapy for head-and-neck cancer

Author:

Tattenberg Sebastian,Liu Peilin,Mulhem Anthony,Cong Xiaoda,Thome Christopher,Ding Xuanfeng

Abstract

Abstract Objective. Proton therapy reduces the integral dose to the patient compared to conventional photon treatments. However, in vivo proton range uncertainties remain a considerable hurdle. Range uncertainty reduction benefits depend on clinical practices. During intensity-modulated proton therapy (IMPT), the target is irradiated from only a few directions, but proton arc therapy (PAT), for which the target is irradiated from dozens of angles, may see clinical implementation by the time considerable range uncertainty reductions are achieved. It is therefore crucial to determine the impact of PAT on range uncertainty reduction benefits. Approach. For twenty head-and-neck cancer patients, four different treatment plans were created: an IMPT and a PAT treatment plan assuming current clinical range uncertainties of 3.5% (IMPT3.5% and PAT3.5%), and an IMPT and a PAT treatment plan assuming that range uncertainties can be reduced to 1% (IMPT1% and PAT1%). Plans were evaluated with respect to target coverage and organ-at-risk doses as well as normal tissue complication probabilities (NTCPs) for parotid glands (endpoint: parotid gland flow <25%) and larynx (endpoint: larynx edema). Main results. Implementation of PAT (IMPT3.5%−PAT3.5%) reduced mean NTCPs in the nominal and worst-case scenario by 3.2 percentage points (pp) and 4.2 pp, respectively. Reducing range uncertainties from 3.5% to 1% during use of IMPT (IMPT3.5%−IMPT1%) reduced evaluated NTCPs by 0.9 pp and 2.0 pp. Benefits of range uncertainty reductions subsequently to PAT implementation (PAT3.5%−PAT1%) were 0.2 pp and 1.0 pp, with considerably higher benefits in bilateral compared to unilateral cases. Significance. The mean clinical benefit of implementing PAT was more than twice as high as the benefit of a 3.5%–1% range uncertainty reduction. Range uncertainty reductions are expected to remain beneficial even after PAT implementation, especially in cases with target positions allowing for full leveraging of the higher number of gantry angles during PAT.

Funder

IBA

Mitacs

National Research Council of Canada

Publisher

IOP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3