A formalism for traceable dosimetry in superficial electronic brachytherapy (eBT)

Author:

de Prez LeonORCID,Avilés Lucas PazORCID,Kok Elfried

Abstract

Abstract Objective. Despite the number of treatments performed with electronic brachytherapy (eBT) there is no uniform methodology for reference dosimetry for international traceability to primary dosimetry standards in different eBT systems. The objective of this study is to propose a formalism for traceability reference dosimetry in superficial eBT, that is easy to apply in the clinic. This method was investigated for an Elekta Esteya with one applicator. Approach. The calibration x-ray spectrum at the primary standards dosimetry laboratory was matched to the measured eBT photon spectrum. Subsequently, two ionization chambers of different types were calibrated at the primary standard dosimetry laboratory (PSDL) in terms of air kerma against a primary standard. The chambers were used to measure ionization chamber reading ratios in-air at different distances from the applicator. Monte Carlo based air kerma ratios were calculated at different positions from the eBT applicator as well as backscatter factors in water and average mass energy absorption ratios in water and in air. Relative measurements with radiochromic films were performed in a water phantom to determine the ratio of absorbed dose to water, D w , at the surface to D w at 1 cm depth in water. These were compared with Monte Carlo calculations. Main results. Calculations and measurements were combined to estimate the D w at the surface and at 1 cm depth in water. Ionization chamber agreement of the surface dose was 1.7%, within an uncertainty of 6.8% (k = 2). They agreed with the manufacturer dosimetry within 1.8%, with an uncertainty of 5.0% (k = 2). The feasibility of the formalism and methodology for the Esteya system was demonstrated. Significance. This study proposes a method for harmonization of traceable reference dosimetry for eBT contact treatments which does not involve a detailed simulation of the ionization chamber. The method demonstrated feasibility for one eBT system using one surface applicator. In the future the method could be applied for different eBT systems.

Funder

European Association of National Metrology Institutes

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference30 articles.

1. Dosimetry formalism and calibration procedure for electronic brachytherapy sources in terms of absorbed dose to water;Abudra’a;Phys. Med. Biol.,2020

2. XCOM: photon cross sections database share facebook linkedin twitter email NIST standard reference database;Berger;National Institute of Standards and Technology,2010

3. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry;Candela-Juan;Med. Phys.,2015

4. Benchmark of penelope for low and medium energy x-rays;Chica;Phys. Med.,2009

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3