Adaptive dual-energy algorithm based on pre-calibrated weighting factors for chest radiography

Author:

Romadanov IvanORCID,Abeywardhana RuwanORCID,Sattarivand Mike

Abstract

Abstract Objective. To develop a dual-energy (DE) algorithm with spatially varying weighting factors for material selection and noise suppression. Approach. Calibration step-phantoms, with overlapping slabs of solid water and bone with different thicknesses, were used to obtain the pre-calibrated material selection and noise reduction weighting factors. The Material selection weighting factors were calculated by finding a zero of contrast-to-noise-ratio (CNR) between regions with two overlapping materials and regions of only target material, while noise suppression weighting factors were determined by maximizing signal-to-noise ratio for overlapping regions. The pre-calibrated weighting factors were fitted with low and high energy radiograph of two Rando phantoms to create maps of material selection and noise suppression weighting factors, which used with DE algorithm and anti-correlated noise reduction (ACNR) algorithm to generate DE images. Three different implementations, including two different sizes of Rando phantoms and two different orientations (oblique and anterior-posterior), were investigated. Soft-tissue and bone only images of Rando phantoms were obtained with five combinations of DE algorithms and CNR, contrast, and noise values of selected regions of interest were compared to evaluate the performance of the novel method: simple log subtraction (SLS), SLS with uniform ACNR, adaptive DE (aDE), aDE with uniform ACNR, and aDE and adaptive ACNR (aACNR). Main results. Compared to SLS, the aDE algorithm demonstrated improved image quality in all three orientations. CNR increased with better contrast for both soft-tissue and bone images. Implementation of aACNR algorithm resulted in further reduction of image noise and improvements in CNR at the cost of contrast. However, aACNR algorithm showed better contrast compared to ACNR method. Significance. A novel DE algorithm was proposed, which showed improved material selection and noise suppression as compared to the conventional DE techniques and can be easily implemented in a clinical environment for real-time DE image generation.

Funder

Atlantic Canada Opportunities Agency

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3