Influence of anatomical structure on antiscatter grid performance in 2D: application to x-ray angiography and a prototype 29:1 ratio grid

Author:

Fetterly KennethORCID,Bernhardt Philipp,Schueler Beth

Abstract

Abstract Objective. The use of uniform phantoms to assess the influence of x-ray scatter and antiscatter grids on x-ray angiography and fluoroscopy image quality disregards the influence of spatially variable x-ray attenuation of patients. The purpose of this work was to measure scatter to primary ratio (SPR) and antiscatter grid SNR improvement factor (K SNR) using experimental conditions which better mimic patient imaging conditions. Approach. Three adult-sized anthropomorphic phantoms were used. AP and lateral projection images of the thorax and abdomen were acquired with and without an antiscatter grid. Grids with ratio 15:1 and 29:1 (r15, r29) and x-ray fields of view 20, 25 (thorax) and 32, 42 cm (abdomen) were tested. Combined with a-priori measurements of grid scatter and primary transmission fractions, these images were used to calculate 2D SPR and K SNR maps. Main results. Results demonstrated that measurements by uniform phantom do not describe the complex 2D SPR and K SNR distributions associated with anthropomorphic phantoms. The regions of the images with the lowest primary x-ray intensity (greatest attenuation) had the highest SPR and the highest K SNR attributable to the grids. Considering all conditions, the 95th percentile of the SPR maps was in the range 42%–185% greater than the median values and that of the K SNR maps was 4%–20% higher than the median values. The combined influences of SID 120 vs. 107 cm and r29 vs. r15 grid resulted in K SNR in the range 1.05–1.49. Significance. Performance of anti-scatter grids using anatomically complex phantoms highlights the substantial variation of SPR and K SNR within 2D images. Also, this work demonstrates the benefit of the prototype r29 grid for thoracic and abdominal angiography imaging conditions is substantial, especially for large patients and radiodense image regions.

Funder

Siemens Healthineers

Publisher

IOP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3