3D phantom for image quality assessment of mammography systems

Author:

Bermúdez J,Roque GORCID,Calderón J,Pardo P,Sánchez M,Ramos V,Ávila C

Abstract

Abstract Objective. To present an innovative approach for the design of a 3D mammographic phantom for medical equipment quality assessment, estimation of the glandular tissue percentage in the patient’s breast, and emulation of microcalcification (μC) breast lesions. Approach. Contrast-to noise ratio (CNR) measurements, as well as spatial resolution and intensity-to-glandularity calibrations under mammography conditions were performed to assess the effectiveness of the phantom. CNR measurements were applied to different groups of calcium hydroxyapatite (HA) and aluminum oxide (AO) μCs ranging from 200 to 600 μm. Spatial resolution was characterized using an aluminum plate contained in the phantom and standard linear figures of merit, such as the line spread function and modulation transfer function (MTF). The intensity-to-glandularity calibration was developed using an x-ray attenuation matrix within the phantom to estimate the glandular tissue percentage in a breast with a compressed thickness of 4 cm. Main results. For the prototype studied, the minimum confidence level for detecting HA μCs is 95.4%, while for AO μCs is above 68.3%. It was also possible to determine that the MTF of the commercial mammography machine used for this study at the Nyquist frequency is 41%. Additionally, a one-to-one intensity-to-glandularity calibration was obtained and verified with Monte-Carlo simulation results. Significance. The phantom provides traditional arrangements presented in accreditation phantoms, which makes it competitive with available devices, but excelling in regarding affordability, modularity, and inlays distribution. Moreover, its design allows to be positioned in close proximity to the patient's breast during a medical screening for a simultaneous x-ray imaging, such that the features of the phantom can be used as reference values to specify characteristics of the real breast tissue, such as proportion of glandular/adipose composition and/or μC type and size lesions.

Funder

Ministry of Science, Technology, and Innovation of Colombia

Faculty of Science of Universidad de los Andes

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference42 articles.

1. Effective lifetime radiation risk for a number of national mammography screening programmes;Ali;Radiography (London, England : 1995),2018

2. Effect of oblique x-ray incidence in flat-panel computed tomography of the breast;Badano;IEEE Trans. Med. Imaging,2009

3. Estimation of the minimum detectable activity of preclinical pet imaging systems with an analytical method;Bao;Med. Phys.,2010

4. Evaluation of the spatial resolution of a CT scanner by direct analysis of the edge response function;Bentzen;Med. Phys.,1983