Effects of tissue heterogeneity and comparisons of collapsed cone and Monte Carlo fast neutron patient dosimetry using the University of Washington clinical neutron therapy system (CNTS)

Author:

Moffitt Gregory B,Sandison George A,Argento David C,Emery Robert,Wootton Landon S,Parvathaneni Upendra,Liao Jay J,Laramore George E,Stewart Robert D

Abstract

Abstract Fast neutron therapy is a high linear energy transfer (LET) radiation treatment modality offering advantages over low LET radiations. Multileaf collimator technology reduces normal-tissue dose (toxicity) and makes neutron therapy more comparable to MV x-ray treatments. Published clinical-trial and other experiences with fast neutron therapy are reported. Early comparative studies failed to consider differences in target-dose spatial conformality between x-ray and neutron treatments, which is especially important for organs-at-risk close to tumor targets. Treatments planning systems (TPS) for high-energy neutrons lag behind TPS tools for MV x-rays, creating challenges for comparative studies of clinical outcomes. A previously published Monte Carlo model of the University of Washington (UW) Clinical Neutron Therapy System (CNTS) is refined and integrated with the RayStation TPS as an external dose planning/verification tool. The collapsed cone (CC) dose calculations in the TPS are based on measured dose profiles and output factors in water, with the absolute dose determined using a tissue-equivalent ionization chamber. For comparison, independent (external) Monte Carlo simulation computes dose on a voxel-by-voxel basis using an atlas that maps Hounsfield Unit (HU) numbers to elemental composition and density. Although the CC algorithm in the TPS accurately computes neutron dose to water compared to Monte Carlo calculations, calculated dose to water differs from bone or tissue depending largely on hydrogen content. Therefore, the elemental composition of tissue and bone, rather than the material or electron density, affects fast neutron dose. While the CC algorithm suffices for reproducible patient dosimetry in fast neutron therapy, adopting methods that consider tissue heterogeneity would enhance patient-specific neutron dose accuracy relative to national standards for other types of ionizing radiation. Corrections for tissue composition have a significant impact on absolute dose and the relative biological effectiveness (RBE) of neutron treatments compared to other radiation types (MV x-rays, protons, and carbon ions).

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3