Polaroid-PET: a PET scanner with detectors fitted with Polaroid for filtering unpolarized optical photons—a Monte Carlo simulation study

Author:

Sanaat AmirhosseinORCID,Ashrafi-Belgabad Aydin,Zaidi HabibORCID

Abstract

Abstract We propose and evaluate the performance of an improved preclinical positron emission tomography (PET) scanner design, referred to as Polaroid-PET, consisting of a detector equipped with a layer of horizontal Polaroid to filter scintillation photons with vertical polarization. This makes it possible to improve the spatial resolution of PET scanners based on monolithic crystals. First, a detector module based on a lutetium-yttrium orthosilicate monolithic crystal with 10 mm thickness and silicon photomultipliers (SiPMs) was implemented in the GEANT4 Monte Carlo toolkit. Subsequently, a layer of Polaroid was inserted between the crystal and the SiPMs. Two preclinical PET scanners based on ten detector modules with and without Polaroid were simulated. The performance of the proposed detector modules and corresponding PET scanner for the two configurations (with and without Polaroid) was assessed using standard performance parameters, including spatial resolution, sensitivity, optical photon ratio detected for positioning, and image quality. The detector module fitted with Polaroid led to higher spatial resolution (1.05 mm FWHM) in comparison with a detector without Polaroid (1.30 mm FHWM) for a point source located at the center of the detector module. From 100% of optical photons produced in the scintillator crystal, 65% and 66% were used for positioning in the detectors without and with Polaroid, respectively. Polaroid-PET resulted in higher axial spatial resolution (0.83 mm FWHM) compared to the scanner without Polaroid (1.01 mm FWHM) for a point source at the center of the field of view (CFOV). The absolute sensitivity at the CFOV was 4.37% and 4.31% for regular and Polaroid-PET, respectively. Planar images of a grid phantom demonstrated the potential of the detector with a Polaroid in distinguishing point sources located at close distances. Our results indicated that Polaroid-PET may improve spatial resolution by filtering the reflected optical photons according to their polarization state, while retaining the high sensitivity expected with monolithic crystal detector blocks.

Funder

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference53 articles.

1. GEANT4—a simulation toolkit;Agostinelli;Nucl. Instrum. Methods Phys. Res. A,2003

2. Geant4 developments and applications;Allison;IEEE Trans. Nucl. Sci.,2006

3. Recent developments in Geant4;Allison;Nucl. Instrum. Methods Phys. Res. A,2016

4. NEMA NU-4 2008 performance evaluation of Xtrim-PET: a prototype SiPM-based preclinical scanner;Amirrashedi;Med. Phys.,2019

5. Polarization imaging: principles and integrated polarimeters;Andreou;IEEE Sens. J.,2002

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. “Building” Human Health: When Doctors and Physicists Work Together;Frontiers for Young Minds;2024-05-21

2. Evaluation of monolithic crystal detector with dual-ended readout utilizing multiplexing method;Physics in Medicine & Biology;2024-04-03

3. The quest for multifunctional and dedicated PET instrumentation with irregular geometries;Annals of Nuclear Medicine;2023-11-12

4. Design and Performance Evaluation of a Dynamic Dual-head Breast PET Scanner Based on LSO and CZT Detector Modules: a Simulation;2022 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC);2022-11-05

5. Enhancing the Partial Geometrical Breast PET Scanner's Images by Deep Learning;2022 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC);2022-11-05