ProTheRaMon—a GATE simulation framework for proton therapy range monitoring using PET imaging
-
Published:2022-11-11
Issue:22
Volume:67
Page:224002
-
ISSN:0031-9155
-
Container-title:Physics in Medicine & Biology
-
language:
-
Short-container-title:Phys. Med. Biol.
Author:
Borys DamianORCID, Baran JakubORCID, Brzeziński KarolORCID, Gajewski JanORCID, Chug Neha, Coussat Aurelien, Czerwiński ErykORCID, Dadgar Meysam, Dulski KamilORCID, Eliyan Kavya VORCID, Gajos AleksanderORCID, Kacprzak Krzysztof, Kapłon ŁukaszORCID, Klimaszewski KonradORCID, Konieczka PawełORCID, Kopeć RenataORCID, Korcyl Grzegorz, Kozik Tomasz, Krzemień WojciechORCID, Kumar Deepak, Lomax Antony J, McNamara Keegan, Niedźwiecki Szymon, Olko PawełORCID, Panek Dominik, Parzych Szymon, Perez del Rio ElenaORCID, Raczyński Lech, Sharma Sushil, Shivani , Shopa Roman YORCID, Skóra TomaszORCID, Skurzok MagdalenaORCID, Stasica PaulinaORCID, Stępień Ewa ŁORCID, Tayefi KeyvanORCID, Tayefi Faranak, Weber Damien CORCID, Winterhalter Carla, Wiślicki WojciechORCID, Moskal PawełORCID, Rucinski AntoniORCID
Abstract
AbstractObjective.This paper reports on the implementation and shows examples of the use of theProTheRaMonframework for simulating the delivery of proton therapy treatment plans and range monitoring using positron emission tomography (PET).ProTheRaMonoffers complete processing of proton therapy treatment plans, patient CT geometries, and intra-treatment PET imaging, taking into account therapy and imaging coordinate systems and activity decay during the PET imaging protocol specific to a given proton therapy facility. We present theProTheRaMonframework and illustrate its potential use case and data processing steps for a patient treated at the Cyclotron Centre Bronowice (CCB) proton therapy center in Krakow, Poland.Approach.TheProTheRaMonframework is based on GATE Monte Carlo software, theCASToRreconstruction package and in-house developed Python and bash scripts. The framework consists of five separated simulation and data processing steps, that can be further optimized according to the user’s needs and specific settings of a given proton therapy facility and PET scanner design.Main results.ProTheRaMonis presented using example data from a patient treated at CCB and the J-PET scanner to demonstrate the application of the framework for proton therapy range monitoring. The output of each simulation and data processing stage is described and visualized.Significance.We demonstrate that theProTheRaMonsimulation platform is a high-performance tool, capable of running on a computational cluster and suitable for multi-parameter studies, with databases consisting of large number of patients, as well as different PET scanner geometries and settings for range monitoring in a clinical environment. Due to its modular structure, theProTheRaMonframework can be adjusted for different proton therapy centers and/or different PET detector geometries. It is available to the community via github (Boryset al2022).
Funder
Fundacja na rzecz Nauki Polskiej Narodowe Centrum Nauki EU Innovative Economy Programme Narodowe Centrum Badań i Rozwoju Excellence Initative—Research University at the Jagiellonian University
Subject
Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|