Towards the standardization of the absorbed dose report mode in high energy photon beams

Author:

Younes TonyORCID,Chauvin MaximeORCID,Delbaere AlexiaORCID,Labour Joey,Fonteny Victoria,Simon Luc,Fares Georges,Vieillevigne Laure

Abstract

Abstract The benefits of using an algorithm that reports absorbed dose-to-medium have been jeopardized by the clinical experience and the experimental protocols that have mainly relied on absorbed dose-to-water. The aim of the present work was to investigate the physical aspects that govern the dosimetry in heterogeneous media using Monte Carlo method and to introduce a formalism for the experimental validation of absorbed dose-to-medium reporting algorithms. Particle fluence spectra computed within the sensitive volume of two simulated detectors (T31016 Pinpoint 3D ionization chamber and EBT3 radiochromic film) placed in different media (water, RW3, lung and bone) were compared to those in the undisturbed media for 6 MV photon beams. A heterogeneity correction factor that takes into account the difference between the detector perturbation in medium and under reference conditions as well as the stopping-power ratios was then derived for all media using cema calculations. Furthermore, the different conversion approaches and Eclipse treatment planning system algorithms were compared against the Monte Carlo absorbed dose reports. The detectors electron fluence perturbation in RW3 and lung media were close to that in water (≤1.5%). However, the perturbation was greater in bone (∼4%) and impacted the spectral shape. It was emphasized that detectors readings should be corrected by the heterogeneity correction factor that ranged from 0.932 in bone to 0.985 in lung. Significant discrepancies were observed between all the absorbed dose reports and conversions, especially in bone (exceeding 10%) and to a lesser extent in RW3. Given the ongoing advances in dose calculation algorithms, it is essential to standardize the absorbed dose report mode with absorbed dose-to-medium as a favoured choice. It was concluded that a retrospective conversion should be avoided and switching from absorbed dose-to-water to absorbed dose-to-medium reporting algorithm should be carried out by a direct comparison of both algorithms.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3