Real-time 4D MRI using MR signature matching (MRSIGMA) on a 1.5T MR-Linac system

Author:

Wu CanORCID,Murray Victor,Siddiq Syed S,Tyagi NeelamORCID,Reyngold Marsha,Crane Christopher,Otazo RicardoORCID

Abstract

Abstract Objective. To develop real-time 4D MRI using MR signature matching (MRSIGMA) for volumetric motion imaging in patients with pancreatic cancer on a 1.5T MR-Linac system. Approach. Two consecutive MRI scans with 3D golden-angle radial stack-of-stars acquisitions were performed on ten patients with inoperable pancreatic cancer. The complete first scan (905 angles) was used to compute a 4D motion dictionary including ten pairs of 3D motion images and signatures. The second scan was used for real-time imaging, where each angle (275 ms) was processed separately to match it to one of the dictionary entries. The complete second scan was also used to compute a 4D reference to assess motion tracking performance. Dice coefficients of the gross tumor volume (GTV) and two organs-at-risk (duodenum-stomach and small bowel) were calculated between signature matching and reference. In addition, volume changes, displacements, center of mass shifts, and Dice scores over time were calculated to characterize motion. Main results. Total imaging latency of MRSIGMA (acquisition + matching) was less than 300 ms. The Dice coefficients were 0.87 ± 0.06 (GTV), 0.86 ± 0.05 (duodenum-stomach), and 0.85 ± 0.05 (small bowel), which indicate high accuracy (high mean value) and low uncertainty (low standard deviation) of MRSIGMA for real-time motion tracking. The center of mass shift was 3.1 ± 2.0 mm (GTV), 5.3 ± 3.0 mm (duodenum-stomach), and 3.4 ± 1.5 mm (small bowel). The Dice scores over time (0.97 ± [0.01–0.03]) were similarly high for MRSIGMA and reference scans in all the three contours. Significance. This work demonstrates the feasibility of real-time 4D MRI using MRSIGMA for volumetric motion tracking on a 1.5T MR-Linac system. The high accuracy and low uncertainty of real-time MRSIGMA is an essential step towards continuous treatment adaptation of tumors affected by real-time respiratory motion and could ultimately improve treatment safety by optimizing ablative dose delivery near gastrointestinal organs.

Funder

National Institutes of Health/National Cancer Institute

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3