Abstract
Abstract
This paper studies the impact of tiny changes in region-of-interest (ROI) tomography system matrices on the variance of the reconstructed ROI. In small-scale and medium-scale examples, the variance in the reconstructed ROI was estimated for different system matrices. The results revealed a striking and counterintuitive phenomenon: a tiny change in the system matrix can dramatically affect the variance of the ROI estimate. In one of our examples, a decrease of 0.1% in one element out of hundreds of thousands of the system matrix resulted in a systematic reduction of the variance inside the ROI, and by a factor of 5 to 10 for some pixels. Our results agree with a recently proven theorem about the ability of additional measurements to reduce the variance in ROI tomography.
Funder
Agence Nationale de la Recherche
Subject
Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Trade-offs between redundancy and increased rank for tomographic system matrices;7th International Conference on Image Formation in X-Ray Computed Tomography;2022-10-18