Dosimetric evaluation of different planning strategies for hypofractionated whole-breast irradiation technique

Author:

Tang Chunbo,Liu Biaoshui,Yuan Jun,He Ji,Xie Ruilian,Huang Minfeng,Niu ShanzhouORCID,Liu Hongdong

Abstract

Abstract Purpose. The dose hotspot areas in hypofractionated whole-breast irradiation (WBI) greatly increase the risk of acute skin toxicity because of the anatomical peculiarities of the breast. In this study, we presented several novel planning strategies that integrate multiple sub-planning target volumes (sub-PTVs), field secondary placement, and RapidPlan models for right-sided hypofractionated WBI. Methods. A total of 35 cases of WBI with a dose of 42.5 Gy for PTVs using tangential intensity-modulated radiotherapy (IMRT) were selected. Both PTVs were planned for simultaneous treatment using the original manual multiple sub-PTV plan (OMMP) and the original manual single-PTV plan (OMSP). The manual field secondary placement multiple sub-PTV plan (m-FSMP) with multiple objects on the original PTV and the manual field secondary placement single-objective plan (m-FSSP) were initially planned, which were distribution-based of V105 (volume receiving 105% of the prescription dose). In addition, two RapidPlan-based plans were developed, including the RapidPlan-based multiple sub-PTVs plan (r-FSMP) and the RapidPlan-based single-PTV plan (r-FSSP). Dosimetric parameters of the plans were compared, and V105 was evaluated using multivariate analysis to determine how it was related to the volume of PTV and the interval of lateral beam angles (ILBA). Results. The lowest mean V105 (5.64 ± 6.5%) of PTV was observed in m-FSMP compared to other manual plans. Upon validation, r-FSSP demonstrated superior dosimetric quality for OAR compared to the two other manual planning methods, except for V5(the volume of ipsilateral lung receiving 5 Gy) of the ipsilateral lung. While r-FSMP showed no significant difference (p = 0.06) compared to r-FSSP, it achieved the lowest V105 value (4.3 ± 4.5%), albeit with a slight increase in the dose to some OARs. Multivariate GEE linear regression showed that V105 is significantly correlated with target volume and ILBA. Conclusions. m-FSMP and r-FSMP can substantially enhance the homogeneity index (HI) and reduce V105, thereby minimizing the risk of acute skin toxicities, even though there may be a slight dose compromise for certain OARs.

Funder

National Natural Science Foundation of China

Jiangxi Double Thousand Plan

Science and Technology Program of Jiangxi Province

Publisher

IOP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3