An automated optimization strategy to design collimator geometry for small field radiation therapy systems

Author:

Wang Jinghui,Wang Lei,Maxim Peter GORCID,Loo Billy WORCID

Abstract

Abstract Purpose. To develop an automated optimization strategy to facilitate collimator design for small-field radiotherapy systems. Methods and Materials. We developed an objective function that links the dose profile characteristics (FWHM, penumbra, and central dose rate) and the treatment head geometric parameters (collimator thickness/radii, source-to-distal-collimator distance (SDC)) for small-field radiotherapy systems. We performed optimization using a downhill simplex algorithm. We applied this optimization strategy to a linac-based radiosurgery system to determine the optimal geometry of four pencil-beam collimators to produce 5, 10, 15, and 20 mm diameter photon beams (from a 6.7 MeV, 2.1 mm FWHM electron beam). Two different optimizations were performed to prioritize minimum penumbra or maximum central dose rate for each beam size. We compared the optimized geometric parameters and dose distributions to an existing clinical system (CyberKnife). Results. When minimum penumbra was prioritized, using the same collimator thickness and SDC (40 cm) as a CyberKnife system, the optimized collimator upstream and downstream radii agreed with the CyberKnife system within 3%–14%, the optimized output factors agreed within 0%–8%, and the optimized transverse and percentage depth dose profiles matched those of the CyberKnife with the penumbras agreeing within 2%. However, when maximum dose rate was prioritized, allowing both the collimator thickness and SDC to change, the central dose rate for larger collimator sizes (10, 15, 20 mm) could be increased by about 1.5–2 times at the cost of 1.5–2 times larger penumbras. No further improvement in central dose rate for the 5 mm beam size could be achieved. Conclusions. We developed an automated optimization strategy to design the collimator geometry for small-field radiation therapy systems. Using this strategy, the penumbra-prioritized dose distribution and geometric parameters agree well with the CyberKnife system as an example, suggesting that this system was designed to prioritize sharp penumbra. This represents proof-of-principle that an automated optimization strategy may apply to more complex collimator designs with multiple optimization parameters.

Funder

National Cancer Institute

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3