Micro-CT imaging of multiple K-edge elements using GaAs and CdTe photon counting detectors

Author:

Allphin A JORCID,Clark D P,Thuering T,Bhandari P,Ghaghada K B,Badea C TORCID

Abstract

Abstract Objective. To evaluate the performance of two photon-counting (PC) detectors based on different detector materials, gallium arsenide (GaAs) and cadmium telluride (CdTe), for PC micro-CT imaging of phantoms with multiple contrast materials. Another objective is to determine if combining these two detectors in the same micro-CT system can offer higher spectral performance and significant artifact reduction compared to a single detector system. Approach. We have constructed a dual-detector, micro-CT system equipped with two PCDs based on different detector materials: gallium arsenide (GaAs) and cadmium telluride (CdTe). We demonstrate the performance of these detectors for PC micro-CT imaging of phantoms with up to 5 contrast materials with K-edges spread across the x-ray spectrum ranging from iodine with a K-edge at 33.2 keV to bismuth with a K-edge at 90.5 keV. We also demonstrate the use of our system to image a mouse prepared with both iodine and bismuth contrast agents to target different biological systems. Main results. When using the same dose and scan parameters, GaAs shows increased low energy (<50 keV) spectral sensitivity and specificity compared to CdTe. However, GaAs performance at high energies suffers from spectral artifacts and has comparatively low photon counts indicating wasted radiation dose. We demonstrate that combining a GaAs-based and a CdTe-based PC detector in the same micro-CT system offers higher spectral performance and significant artifact reduction compared to a single detector system. Significance. More accurate PC micro-CT using a GaAs PCD alone or in combination with a CdTe PCD could serve for developing new contrast agents such as nanoparticles that show promise in the developing field of theranostics (therapy and diagnostics).

Funder

National Cancer Institute

National Institute on Aging

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3