X-ray CT adaptation based on a 2D–3D deformable image registration framework using simulated in-room proton radiographies

Author:

Palaniappan Prasannakumar,Meyer SebastianORCID,Rädler Martin,Kamp Florian,Belka Claus,Riboldi Marco,Parodi KatiaORCID,Gianoli Chiara

Abstract

Abstract The aim of this work is to investigate in-room proton radiographies to compensate realistic rigid and non-rigid transformations in clinical-like scenarios based on 2D–3D deformable image registration (DIR) framework towards future clinical implementation of adaptive radiation therapy (ART). Monte Carlo simulations of proton radiographies (pRads) based on clinical x-ray CT of a head and neck, and a brain tumor patients are simulated for two different detector configurations (i.e. integration-mode and list-mode detectors) including high and low proton statistics. A realistic deformation, derived from cone beam CT of the patient, is applied to the treatment planning CT. Rigid inaccuracies in patient positioning are also applied and the effect of small, medium and large fields of view (FOVs) is investigated. A stopping criterion, as desirable in realistic scenarios devoid of ground truth proton CT (pCT), is proposed and investigated. Results show that rigid and non-rigid transformations can be compensated based on a limited number of low dose pRads. The root mean square error with respect to the pCT shows that the 2D–3D DIR of the treatment planning CT based on 10 pRads from integration-mode data and 2 pRads from list-mode data is capable of achieving comparable accuracy (∼90% and >90%, respectively) to conventional 3D–3D DIR. The dice similarity coefficient over the segmented regions of interest also verifies the improvement in accuracy prior to and after 2D–3D DIR. No relevant changes in accuracy are found between high and low proton statistics except for 2 pRads from integration-mode data. The impact of FOV size is negligible. The convergence of the metric adopted for the stopping criterion indicates the optimal convergence of the 2D–3D DIR. This work represents a further step towards the potential implementation of ART in proton therapy. Further computational optimization is however required to enable extensive clinical validation.

Funder

Deutsche Forschungsgemeinschaft

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3