A statistical alternative to current measures of image quality in digital mammography

Author:

Caldwell DORCID,Baldelli PORCID,Phelan N,Kenny P

Abstract

Abstract Objective. Mammogram image quality in European breast screening systems is defined by threshold gold thickness (T) assessment of the CDMAM contrast-detail phantom. Previous studies have outlined several limitations of the phantom including expense, number of images required and inter-phantom manufacturing variability. Two alternative approaches to image quality assessment for routine quality control are examined and compared to the CDMAM technique: (i) A detectability index (d′) based on a non-prewhitened model observer with an eye filter (NPWE) and (ii) A statistical estimate of contrast based on image noise levels (CSTAT ). Approach. The d′ calculation follows a previously published methodology based on the NNPS and contrast, both measured from an image of 5 cm of PMMA containing a 0.2 mm Al target, as well as the MTF measured under standard conditions. For the proposed statistical method, pixels in the centre of the same NNPS image were re-binned into a range of equivalent CDMAM target areas. For any area, the minimum contrast necessary to distinguish a signal from the background, CSTAT , is 3.29σ at a 95% level of confidence, where σ is the standard deviation of the background pixels. Theoretical analysis predicts a simple relationships between CSTAT , T and d′. Measured values of CSTAT were compared to T and d′ as a function of air kerma at the detector for ten digital mammography systems from three different manufacturers. Main Results. Theoretical relationships between CSTAT , d′ and T were demonstrated. Minimum acceptable image quality performance for 0.10 and 0.25 mm diameter discs, defined by the European Guidelines in terms of T, are equivalent to d′ values of 0.85 and 5.36 and threshold CSTAT values of 0.055 and 0.022. Significance. Strong correlations between log(T), log(d′) and log(CSTAT ) suggest that either alternative approach produces information corresponding to that obtained using the CDMAM. CSTAT should be considered as a simple, objective and cost-effective alternative to routine image quality assessment in mammography.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3